ARC 350
ARC 350
Universal electrosurgery unit
The ARC 350 offers all available electrosurgical functions. In addition to bipolar resection applications in urology and gynaecology and LIGATION sealing of vessels, further programs provide reproducible results for specific indications (e.g. for neurosurgery or cardiothoracic surgery).
The HF unit is intended exclusively for the generation of electrical power for monopolar and bipolar cutting and coagulation in surgical interventions involving tissue.
Excellent results depend on the right technology. In addition to the innovative socket design that allows
up to two monopolar and two bipolar instruments
to be attached simultaneously and is compatible
with all popular standard connections, there are
numerous hardware and software components that
can also directly affect performance in the OR.
– ARC control arc regulation for reproducible
monopolar and bipolar cutting results
– Up to 9 effects per mode
– EASY neutral electrode monitoring with contact
monitor, baby mode with automatic power limitation
– Current leakage monitoring
– Short circuit detection
– ISSys permanent system self-testing
– CCS permanent initial cutting support
– Configurable socket design
– Information area for device messages
– CUT modes: e.g. standard, dry, cardiac, GastroCut
loop and knife, MetraLOOP, laparoscopy
– Micro-regulations and power forms for plastic and
neurosurgery down to 0.1 W
– COAG modes: moderate, forced, spray, cardiac
– Autostart function
Monopolar simultaneous coagulation
With the ARC 350, monopolar simultaneous
coagulation permits the simultaneous COAG
activation of two monopolar handles for consistent
tissue effects. This mode is especially ideal for
coagulation and preparation, with the selected
power setting being available for both handles.
Applications include gynaecology with mastectomies,
cardiac surgery with bypasses and surgery
with multiple traumas.
Technical data at a glance | ARC 350 | ARC PLUS |
Mains voltage | 100- 120 V/220-240 V ± 10% | 100-240 V г 10% |
Mains frequency | 50 / 60 Hz | 50 / 60 Hz |
Mains power | Max. 10 A / 5 A | Max. 0.6 A |
Mains fuse | T 10A/5A | T 1 A |
Power consumption in standby mode | 3 W | 5 W |
Power consumption at max. | 700 W | 32 W |
Width * Height x Depth | 430 x 180 x475 mm | 433 x 97 x 489 mm |
Weight | 12.5 kg | 7.7 kg |
Classification under EC Directive 93 / 42 / EEC | II b | II a |
Protection class according to EN 60601-1 | 1 | 1 |
Type according to EN 60 601-1 | CF | CF |
CE marking | CEO123 | CE0123 |
Item no. | 900-351 | 900-001 |
GastroCut ind. COMFORT | 900-391 | |
Bipolar resection ind. COMFORT | 900-395 | |
LIGATION ind. COMFORT | 900-396 | |
Maximum CUT power | 350 W | |
Maximum COAG power | 350 W (Bipolar resection) | |
Mains frequency | 350 kHz / 1 MHz |