ARC 350

Universal electrosurgery unit

Поделиться

The ARC 350 offers all available electrosurgical functions. In addition to bipolar resection applications in urology and gynaecology and LIGATION sealing of vessels, further programs provide reproducible results for specific indications (e.g. for neurosurgery or cardiothoracic surgery).

The HF unit is intended exclusively for the generation of electrical power for monopolar and bipolar cutting and coagulation in surgical interventions involving tissue.

Excellent results depend on the right technology. In addition to the innovative socket design that allows
up to two monopolar and two bipolar instruments
to be attached simultaneously and is compatible
with all popular standard connections, there are
numerous hardware and software components that
can also directly affect performance in the OR.
– ARC control arc regulation for reproducible
monopolar and bipolar cutting results
– Up to 9 effects per mode
– EASY neutral electrode monitoring with contact
monitor, baby mode with automatic power limitation
– Current leakage monitoring
– Short circuit detection
– ISSys permanent system self-testing
– CCS permanent initial cutting support
– Configurable socket design
– Information area for device messages
– CUT modes: e.g. standard, dry, cardiac, GastroCut
loop and knife, MetraLOOP, laparoscopy
– Micro-regulations and power forms for plastic and
neurosurgery down to 0.1 W
– COAG modes: moderate, forced, spray, cardiac
– Autostart function

Monopolar simultaneous coagulation
With the ARC 350, monopolar simultaneous
coagulation permits the simultaneous COAG
activation of two monopolar handles for consistent
tissue effects. This mode is especially ideal for
coagulation and preparation, with the selected
power setting being available for both handles.
Applications include gynaecology with mastectomies,
cardiac surgery with bypasses and surgery
with multiple traumas.

Technical data at a glance ARC 350 ARC PLUS
Mains voltage 100- 120 V/220-240 V ± 10% 100-240 V г 10%
Mains frequency 50 / 60 Hz 50 / 60 Hz
Mains power Max. 10 A / 5 A Max. 0.6 A
Mains fuse T 10A/5A T 1 A
Power consumption in standby mode 3 W 5 W
Power consumption at max. 700 W 32 W
Width * Height x Depth 430 x 180 x475 mm 433 x 97 x 489 mm
Weight 12.5 kg 7.7 kg
Classification under EC Directive 93 / 42 / EEC II b II a
Protection class according to EN 60601-1 1 1
Type according to EN 60 601-1 CF CF
CE marking CEO123 CE0123
Item no. 900-351 900-001
GastroCut ind. COMFORT 900-391  
Bipolar resection ind. COMFORT 900-395  
LIGATION ind. COMFORT 900-396  
Maximum CUT power 350 W  
Maximum COAG power 350 W (Bipolar resection)  
Mains frequency 350 kHz / 1 MHz